Overview: SOLUM and Infineon Target 800Vdc AI Rack Backup Power

On November 5, 2026, South Korea’s SOLUM, a server power supply designer and manufacturer listed on the Korea Exchange under ticker 248070, announced that it had signed a memorandum of understanding with Infineon on high-voltage direct current power solutions for AI data centers. The agreement expands an existing collaboration and covers three applications: intermediate bus converters, battery backup units and power supply units. Alongside the signing, SOLUM unveiled a 26kW-class BBU DC/DC converter for 800Vdc racks and set a target of volume production in 2027. The timing reflects rising backup-power and conversion demands as AI rack densities increase.

MoU Scope: Three Power Conversion Blocks

The MoU is structured around IBCs, BBUs and PSUs. According to SOLUM’s announcement, Infineon will participate from the early stages of SOLUM’s related projects, reviewing suitable technologies and products, providing reference designs and offering technical support. The work will use Infineon’s silicon, silicon carbide and gallium nitride power semiconductors and control solutions. SOLUM will contribute its own server power design and manufacturing capabilities to develop power products for AI data centers and aims to win adoption with global customers. The two companies will also continue regular technical dialogue on next-generation development.

Technical Details: 26kW BBU Converter and Efficiency Target

The centerpiece shown at a technology event at SOLUM’s site in Yongin, South Korea, was a 26kW-class BBU DC/DC converter for 800Vdc rack power architectures. It is intended to keep AI servers running through momentary power outages. The converter uses Infineon CoolSiC MOSFETs, EiceDRIVER gate drivers and PSOC digital power controllers, and it is being developed to reach peak efficiency above 98.5%. That efficiency figure is a development target, not a measured value for production units. SOLUM also displayed a BBU DC/DC converter for low-voltage direct current, an ORv3-compatible 33kW power shelf and server PSUs, indicating that it is preparing products for both 800Vdc and conventional low-voltage racks at the same time. Of the three applications covered by the MoU, only the BBU came with a concrete performance target and production timing; no product specifications were disclosed for the IBC and PSU.

Why 800Vdc Racks Need a New Backup-Power Class

AI data centers are pushing rack power density higher, which raises the importance of backup power and power conversion. The BBU’s role in the rack is to keep supplying servers with power during momentary outages. As racks move to 800Vdc architectures, backup and conversion hardware must be designed for that higher-voltage DC environment. The 26kW-class BBU converter is aimed at that requirement. The efficiency target above 98.5% shows that conversion losses are a central design concern, but the announced number should not be treated as a production specification. Comparisons require checking the evaluation conditions used for any measured result.

Market Context: A Maturing Division of Labor

Infineon’s Adam White, Division President Power Systems, said AI data centers demand a higher level of efficiency, reliability and power density from power infrastructure, and that SOLUM’s server power capabilities complement Infineon’s semiconductors. In October, Infineon released a reference design for a 27kW three-phase AI server PSU, and in its 800VDC power collaboration with NVIDIA it has announced that it will use GaN in the IBC. A division of labor in which semiconductor makers provide reference designs and power supply makers turn them into products and mass-produce them is taking hold in 800Vdc power delivery as well.

Industry Impact: Beyond the Major Power Suppliers

Attention in AI data center power tends to focus on the large power supply makers, but a Korean power supply maker naming the North American market and setting a production timeline for 800Vdc products widens the pool of candidate suppliers. SOLUM CEO Jun Sung-ho said the collaboration with Infineon will strengthen the company’s high-voltage, high-efficiency power design capabilities and that it will pursue new business opportunities in the next-generation AI data center power market, including North America. If the 2027 volume production target is met, BBUs for racks that have moved to 800Vdc can be sourced from power supply makers building on designs from a semiconductor maker that offers Si, SiC and GaN. However, an MoU is not a contract: the agreement includes no monetary amount, volume or specific customer.

Implications for Design and Procurement Teams

  • More options for 800Vdc BBUs: if the 2027 target is met, procurement teams will have additional sources for backup-power converters designed for 800Vdc racks.
  • Efficiency above 98.5% is a target: the announced figure is not a measured production value, so comparisons require checking evaluation conditions.
  • An MoU is not a contract: no monetary amount, volume or specific customer was disclosed, and no product specifications were given for the IBC and PSU.
  • Supply chains beyond the majors are moving: a Korean power supply maker naming North America and setting a 2027 production timeline broadens the candidate supplier pool.

Future Outlook: What to Watch Before 2027

The next milestones are product qualification and production readiness. The original announcement does not specify customer commitments or volumes, so design and procurement teams should watch for measured efficiency data, evaluation conditions, IBC and PSU specifications, and whether 800Vdc BBU designs are validated in full rack architectures. The MoU signals intent and a direction of travel; 2027 volume production remains a target rather than a confirmed shipment plan.